3/3
RF Signal processing : VWA 00060 AB
VWA 00060 AB xx DS Rev 0.1
DATA SHEET
VWA
Pr
r
od
d
uct
t
-
-
L
L
i
i
ne
Head Office : rue de la Croix Blanche - Immeuble LOGI – 78350 France
+ 33 (0)619 870 560
+33 (0)139 564 012
mail :
VWA 00060 AB xx DS Rev 0.1
VectraWave Proprietary information subject to change without notice
October 08 p 3 /3
Pin out and pin description
Pad # Function
Pad # Function
Pad # Function
Pad # Function
1
Ground
13
Ground
25
Ground
37
Ground
2
Ground
14
Ground
26
Ground
38
Ground
3
Ground
15
Ground
27
Ground
39
Ground
4
Vdd1
16
Vph
28
Output
40
Ground
5
Ground
17
Ground
29
Ground
41
Ground
6
Ground
18
NC
30
Vdd2
42
Vagc
7
Ground
19
Ground
31
Ground
43
Ground
8
Ground
20
NC
32
Vdet
44
Vcc
9
Ground
21
Ground
33
Ground
45
Ground
10
Input
22
Ground
34
Vref
46
Ground
11
Ground
23
Ground
35
Ground
47
Ground
12
Ground
24
Ground
36
Ground
48
Ground
Handling
This product is sensitive to electrostatic discharge and
should not be handled except at a static free
workstation. Take precautions to prevent ESD; use
wrist straps, grounded work surfaces and recognized
anti-static techniques when handling the
20
G-PSDD-4
modules.
Ordering information
Product code Name
VWA 00060 AB 20G-PSDD-4 SMD 540°Phase shifter
VWA 00061 AB Demonstration board equipped
w/phase shifter VWA 00060 AA
Care should be taken to avoid supply transient and over
voltage. Over voltage above the maximum specified in
absolute maximum rating section may cause permanent
damage to the device.