Office : Z.I. des Loges, rue de la Croix Blanche - 78350 Les Loges en Josas - France
Website :
• Phone : + 33 (0)619 870 560 • Fax : +33 (0)139 564 012 • Mail :
VectraWave Proprietary information subject to change without notice
111
2/3
High Speed Communication, Data drivers : VWA 00022 AB
VWA 00022 AAxx DS Rev 1.41
DATA SHEET
VW
Pr
r
o
o
d
d
u
u
ct
t
-
-
L
L
i
i
ne
Head Office : rue de la Croix Blanche - Immeuble LOGI – 78350 France
+ 33 (0)619 870 560
+33 (0)139 564 012
mail :
VWA 00022 AAxx
a ave Proprietary information subject to change without no
09 p 2 /3
Typical Eye diagram:
Data Out
DATA OUT Measurements
Vc =
0,29
V
Ibias
273,0
mA
Eye Amplitude:
6,57
Vpp
Eye Height:
5,74
Vpp
Eye Width:
80,3
ps
Rise Time:
28,0
ps
Fall Time:
30,6
ps
Jitter RMS:
2,4
ps
Jitter pp:
12,1
ps
Crossing%:
45,7
%
Jitter DRIVER
Jitter RMS:
0,7
ps
Jitter pp:
3,9
ps
DATA OUT Measurements
Vc =
1,69
V
Ibias
293,0
mA
Eye Amplitude:
7,58
Vpp
Eye Height:
6,64
Vpp
Eye Width:
79,7
ps
Rise Time:
32,8
ps
Fall Time:
30,2
ps
Jitter RMS:
2,5
ps
Jitter pp:
12,4
ps
Crossing %:
49,5
%
Jitter DRIVER
Jitter RMS:
0,5
ps
Jitter pp:
4,8
ps
DATA OUT Measurements
Vc =
3,00
V
Ibias
309,0
mA
Eye Amplitude:
8,36
Vpp
Eye Height:
7,36
Vpp
Eye Width:
79,6
ps
Rise Time:
34,5
ps
Fall Time:
30,0
ps
Jitter RMS:
2,4
ps
Jitter pp:
11,7
ps
Crossing %:
53,4
%
Jitter DRIVER
Jitter RMS:
0,5
ps
Jitter pp:
2,1
ps
Mechanical characteristics
Test Set
Data In
MP 1800
10,709
Gb/s
2
31-1
3
dB
26
dB 86100A
83484
A
12,0
V
Ibias
Vc
DUT
Pin Out
Handling
This product is sensitive to electrostatic discharge and
should not be handled except at a static free
workstation. Take precautions to prevent ESD; use
wrist straps, grounded work surfaces and recognized
anti-static techniques when handling the
VWA-15-VA-257
module.
Care should be taken to avoid supply transient and over
voltage. Over voltage above the maximum specified in
absolute maximum rating section may cause permanent
damage to the device.
Pin Nb
Designation
1
Input
2
Output
3
Vbias
4
Ground
5
V
c