Typical Characteristics:
Tamb = 25°C, VD = +8V, ID = 2,2A, measured in pulsed mode for F= 10 KHz and duty cycle 10%.
Parameter measured in pulse mode
Symbol
Min
Typ
Max Unit
Frequency range
F
8
12
GHz
Small signal Gain from 8 to 12 GHz
G
24
dB
Large signal Gain flatness from 9 to 11 GHz
G
+/- 0,25
dB
Input adaptation from 8 to 12 GHz
S11
10
dB
Output adaptation from 8 to 12 GHz
S22
10
dB
Saturated output power
PSat
+39
dBm
Operating Drain supply voltage
VD
8
V
Supply current total for Vg= -1,4V
ID
2,2
A
Environmental parameters
Environment Parameters
Symbols
Min
Max
Units
Storage temperature
Tst
-55
+85
°C
Operating temperature
Top
-40
+85
°C
Absolute maximum ratings
Maximum ratings
Symbols
Min
Max
Units
Compression level
Cmp
6
dbc
Drain Voltage without RF input
VD
10
V
Supply Quiescent current
ID
2,8
A
Supply current in saturation
ID_Sat
4
A
RF input power (In)
Pin max
+15
dBm
Care should be taken to avoid supply transient and over voltage. Over voltage above the maximum specified in absolute