Head Office : Z.I. des Loges, rue de la Croix Blanche - 78350 Les Loges en Josas - France
Website :
• Phone : + 33 (0)619 870 560 • Fax : +33 (0)139 564 012 • Mail :
VectraWave Proprietary information subject to change without notice
125
3/5
Hight Speed Communication / RF - Optical Assemblies : VLI 00005 AA
VLI00005 AA xx DS Rev0.1
DATA SHEET
VLI
Pr
r
od
d
u
u
c
c
t
t
-
-
Li
i
n
n
e
Head Office : rue de la Croix Blanche - Immeuble LOGI – 78350 France
+ 33 (0)619 870 560
+33 (0)139 564 012
mail :
VLI 00005 AA xx DS Rev0.1
VectraWave Proprietary information subject to change without notice
February 08 p 3 /5
Front panel controls
Name
Symbol Function
Test Button
BT Active when in “1” position : allow a,b,c and d manual setting, Ip manual setting, Ip
monitoring and CW current drive (Ip+
ip)
Trig enable
sc
Disable Clk trigger function when in logical “1”.
Manual A set
a
Defines A (
ip) value for testing, when BT = “1”.
Manual B set
b Defines B (
ip) value for testing, when BT = “1”.
Manual C set
c
Defines C (
ip) value for testing, when BT = “1”.
Manual D set
d Defines D (
ip) value for testing, when BT = “1”.
Current monitoring
Ip Access to a voltage value image of the current (total)
Ip setting +
Ip + Pushing the Ip+ button will increase the Ip value (64 steps)
Ip setting -
Ip -
Pushing the Ip- button will decrease the Ip value (64 steps)
Groung
GND Ground reference for Ip and T°C voltage
Bias
current
monitoring
Ibias Access to a voltage value image of the bias current Ibias
Ibias setting +
Ibias + Pushing the Ibias+ button will increase the Ibias value (64 steps)
Ibias setting -
Ibias - Pushing the Ibias- button will decrease the Ibias value (64 steps)
Temperature
monitoring
Access to a voltage value image of the optoelectronic device.
LED color code : green = 25°C, blue <24°C, red>26°C
Stand by
SD Stand by mode, no control, no current, low power consumption.